Mon interlocuteur
Sélectionner un département

chainflex® bus cable CFROBOT8.PLUS

  • Sollicitation: Pour les sollicitations en torsion
  • Gaine extérieure: PUR
  • Blindage général
  • Résistant aux liquides de refroidissement
  • Résistant aux entailles
  • Résistance aux huiles: Résistant aux huiles (selon DIN EN 50363-10-2)
  • Non propagateur de flamme
  • Résistant à l'hydrolyse et aux microbes
  • Résistant aux UV
  • Classe chainflex®: 6.1.3.4
Description de produit
chainflex® bus cable CFROBOT8.PLUS
 
Typical application areas
  • For extremely heavy duty applications with torsion movements
  • Almost unlimited resistance to oil, also with bio-oils
  • Indoor and outdoor applications, UV resistant
  • Especially for robots and 3D movements, handling, lead screw drives
Guaranteed service life for this series according to the guarantee conditions
More information: Garantie chainflex®
Cycles *  5 million7.5 million10 million
Temperature,v max. [°/s]a max. [°/s²]Torsion max.R min. [factor x d]R min. [factor x d]
from/to [°C]TwistedTwisted[°/m][°/m][°/m]
-25 / -15  ±330±240±150
-15 / +6036060±360±270±180
+60 / +70  ±330±240±150
* Higher number of cycles possible - please ask for your individual calculation.
 
Technical note bus cables
 
chainflex® bus cables are specially developed and tested for continuous use in e-chains® applications. Depending on
the used outer jacket material and the design principle, the bus cables are designed for different mechanical requirements
and media resistances.
The electrical design is selected in such a way that, on the one hand, the electrical properties of the respective bus specification are reliably fulfilled, and the greatest importance is also placed on high EMC safety. A permanent stability of the electrical values despite permanent movement is also ensured.
However, the entire transmission property in a complete bus communication system is not exclusively
dependent on the cable used. Rather, it requires an exact coordination of all components (electronic components,
connection technology and cable) as well as the consideration of the maximum transmission rates which are dependent on the respective systems
in relation to the required data transmission rates. A cable is therefore not solely responsible for the secure transmission of the
signals.
igus® advises you in the design of the appropriate bus system, taking into account all these factors and carrying out extensive tests to
ensure the process reliability of your system from the start.
 
 
Certifications et normes
Résistance aux UV<br>Haute Sans silicone<br>Sans substances gênant l´imprégnation (selon PV 3.10.7 – version 1992) UL/CSA<br>Style 10258 et 21387, 1 000 V, 90°C EAC<br>Certifié selon no TC RU C-DE. ME77.B.01218 CTP<br>Certifié selon no C-DE. PB49.B.00416 Sans plomb<br>Selon la directive 2011/65/UE (RoHS-II) CEI<br>Selon CEI 20-35 Salles blanches<br>Conforme ISO classe 1. Matériau de gaine extérieure comme CF27.07.05.02.01.D, contrôlé par l´IPA en vertu de la norme ISO 14644-1 CE<br>Selon 2014/35/UE
Données techniques
Téléchargements

Conseil

Je me réjouis par avance de répondre à vos questions

Livraison et conseil technique

En personne :

Du lundi au vendredi de 8h à 20h. Le samedi de 8h à 12h à Cologne en Allemagne

En ligne :

24h/24